PECI Thermal Monitoring

Configure PECI (Platform Environment Control Interface) to read CPU and DIMM temperatures through the BMC.

Table of Contents

  1. Overview
  2. Architecture
    1. Protocol Fundamentals
    2. CPU Address Assignment
    3. PECI Command Types
    4. Software Stack
    5. D-Bus Interfaces
    6. Key Dependencies
  3. Configuration
    1. Kernel Driver Configuration
    2. Device Tree Configuration
      1. AST2600 Example
    3. Build-Time Configuration (Yocto)
    4. Meson Build Options (dbus-sensors)
  4. Entity Manager PECI Configuration
    1. Configuration File
    2. Entity Manager Properties for PECI
    3. Deploying Configuration via bbappend
  5. Porting Guide
    1. Step 1: Prerequisites
    2. Step 2: Configure the Device Tree
    3. Step 3: Enable Kernel Drivers
    4. Step 4: Create Entity Manager Configuration
    5. Step 5: Build and Verify
  6. Verifying PECI Sensors
    1. Verify Kernel Drivers and Hwmon
    2. Read Raw Hwmon Values
    3. Test with peci_cmds
    4. Verify D-Bus Sensors
    5. Verify via Redfish
  7. Code Examples
    1. Example 1: PECI Health Check Script
    2. Example 2: Reading PECI Sensors via D-Bus (Python)
  8. Troubleshooting
    1. Issue: PECI Ping Fails (No Response from CPU)
    2. Issue: Kernel Driver Not Loaded
    3. Issue: Hwmon Devices Not Created
    4. Issue: D-Bus Sensors Show NaN
    5. Issue: DIMM Temperatures Not Available
    6. Debug Commands
  9. References
    1. Official Resources
    2. Related Guides
    3. External Documentation

Overview

PECI (Platform Environment Control Interface) is Intel’s single-wire serial bus that connects the BMC to one or more host CPUs. Through PECI, the BMC reads CPU die temperatures, DIMM temperatures, package configuration data, and model-specific registers – all without consuming an I2C bus or requiring the host OS to be running.

On OpenBMC, PECI thermal monitoring involves three layers: the ASPEED PECI hardware controller, Linux kernel PECI drivers that expose readings through hwmon sysfs, and dbus-sensors daemons that publish those readings on D-Bus for consumption by bmcweb, ipmid, and fan control.

This guide walks you through the full stack: understanding the PECI protocol, configuring the device tree and kernel drivers, setting up Entity Manager for sensor discovery, reading temperatures through D-Bus and Redfish, and diagnosing common failures.

Key concepts covered:

  • PECI single-wire protocol and CPU addressing (0x30, 0x31)
  • PECI command types: Ping, GetTemp, RdPkgConfig, RdIAMSR
  • Kernel drivers: peci-aspeed, peci-cputemp, peci-dimmtemp
  • Device tree configuration for AST2500/AST2600
  • dbus-sensors integration with Entity Manager
  • Troubleshooting PECI connectivity and sensor failures

PECI is not testable in QEMU. The QEMU AST2600 model does not emulate the PECI controller or CPU thermal data. You need physical hardware with an Intel CPU connected via PECI to test this guide.


Architecture

PECI uses a single wire between the BMC and each CPU socket. The BMC acts as the originator (master) and each CPU acts as a responder (client). The bus operates at 2 kbps to 2 Mbps, negotiated automatically.

Protocol Fundamentals

┌─────────────────────────────────────────────────────────────────────────┐
│                        PECI Bus Topology                                │
├─────────────────────────────────────────────────────────────────────────┤
│                                                                         │
│   ┌───────────────┐         Single Wire (PECI)                          │
│   │     BMC       │──────────────────────────┬──────────────────────┐   │
│   │  (Originator) │                          │                      │   │
│   │  ASPEED       │                  ┌───────┴───────┐      ┌───────┴───────┐
│   │  AST2500/2600 │                  │    CPU 0      │      │    CPU 1      │
│   └───────────────┘                  │  (Responder)  │      │  (Responder)  │
│                                      │  Addr: 0x30   │      │  Addr: 0x31   │
│                                      └───────────────┘      └───────────────┘
│                                                                         │
│   Signal: Open-drain, negotiated bit rate                               │
│   Voltage: 1.1V nominal (varies by CPU generation)                      │
│   Max clients: Typically 2 (dual-socket), up to 8 by spec              │
│                                                                         │
└─────────────────────────────────────────────────────────────────────────┘

CPU Address Assignment

Each CPU on the PECI bus has a fixed address determined by its socket position:

Socket PECI Address Description
CPU 0 0x30 First processor socket
CPU 1 0x31 Second processor socket
CPU 2 0x32 Third processor socket (4S platforms)
CPU 3 0x33 Fourth processor socket (4S platforms)

PECI addresses are hardwired by the CPU socket position on the motherboard. You do not configure them in software.

PECI Command Types

Command Code Description Typical Use
Ping 0x00 Check if CPU is alive and responding Connectivity test
GetTemp 0x01 Read CPU die temperature (DTS) Primary thermal monitoring
RdPkgConfig 0xA1 Read package configuration data DIMM temps, TDP, core count
WrPkgConfig 0xA5 Write package configuration data Set thermal thresholds
RdIAMSR 0xB1 Read IA model-specific register Power, frequency, C-state data

GetTemp returns the CPU die temperature as a relative value below the thermal control circuit (TCC) activation temperature. The kernel driver converts this to an absolute temperature using the TCC offset stored in the CPU’s package configuration.

Software Stack

┌─────────────────────────────────────────────────────────────────────────┐
│                    PECI Thermal Monitoring Stack                        │
├─────────────────────────────────────────────────────────────────────────┤
│                                                                         │
│  ┌──────────────────────────────────────────────────────────────────┐   │
│  │  D-Bus Consumers: bmcweb (Redfish)  │  ipmid  │  fan-control    │   │
│  └────────────────────────────┬─────────────────────────────────────┘   │
│                               │                                         │
│  ┌────────────────────────────┴─────────────────────────────────────┐   │
│  │  D-Bus: xyz.openbmc_project.Sensor.Value                        │   │
│  │  /xyz/openbmc_project/sensors/temperature/CPU0_Temp              │   │
│  │  /xyz/openbmc_project/sensors/temperature/CPU0_DIMM0_Temp       │   │
│  └────────────────────────────┬─────────────────────────────────────┘   │
│                               │                                         │
│  ┌────────────────────────────┴─────────────────────────────────────┐   │
│  │  dbus-sensors PECISensor (configured via Entity Manager JSON)   │   │
│  └────────────────────────────┬─────────────────────────────────────┘   │
│                               │                                         │
│  ┌────────────────────────────┴─────────────────────────────────────┐   │
│  │  Kernel: peci-cputemp, peci-dimmtemp ──> /sys/class/hwmon/      │   │
│  │          peci-aspeed ──> PECI bus controller                     │   │
│  └────────────────────────────┬─────────────────────────────────────┘   │
│                               │                                         │
│  ┌────────────────────────────┴─────────────────────────────────────┐   │
│  │  Hardware: AST2500/AST2600 PECI Controller ←── Wire ──→ CPU(s)  │   │
│  └──────────────────────────────────────────────────────────────────┘   │
│                                                                         │
└─────────────────────────────────────────────────────────────────────────┘

D-Bus Interfaces

Interface Object Path Description
xyz.openbmc_project.Sensor.Value /xyz/openbmc_project/sensors/temperature/<name> CPU or DIMM temperature reading
xyz.openbmc_project.Sensor.Threshold.Warning /xyz/openbmc_project/sensors/temperature/<name> Warning threshold levels
xyz.openbmc_project.Sensor.Threshold.Critical /xyz/openbmc_project/sensors/temperature/<name> Critical threshold levels

Key Dependencies

  • peci-aspeed: Kernel driver for the ASPEED PECI hardware controller
  • peci-cputemp: Reads CPU die temperatures via PECI GetTemp command
  • peci-dimmtemp: Reads DIMM temperatures via PECI RdPkgConfig command
  • dbus-sensors: Polls hwmon sysfs and publishes readings on D-Bus
  • Entity Manager: JSON-based configuration for PECI sensor discovery

Configuration

Kernel Driver Configuration

The PECI subsystem requires three kernel drivers working together:

Driver Module Purpose
peci-aspeed peci_aspeed Controls the ASPEED SoC PECI hardware engine
peci-cputemp peci_cputemp Reads CPU die temperature via GetTemp command
peci-dimmtemp peci_dimmtemp Reads DIMM temperatures via RdPkgConfig command

Enable these options in your kernel configuration fragment (e.g., peci.cfg):

CONFIG_PECI=y
CONFIG_PECI_ASPEED=y
CONFIG_SENSORS_PECI_CPUTEMP=y
CONFIG_SENSORS_PECI_DIMMTEMP=y

Device Tree Configuration

Add the PECI controller and client sub-nodes for each CPU socket in your platform device tree.

AST2600 Example

/* aspeed-bmc-myplatform.dts */
&peci0 {
    status = "okay";

    /* CPU 0 at PECI address 0x30 */
    peci-client@30 {
        compatible = "intel,peci-client";
        reg = <0x30>;
    };

    /* CPU 1 at PECI address 0x31 (dual-socket only) */
    peci-client@31 {
        compatible = "intel,peci-client";
        reg = <0x31>;
    };
};

The reg value must match the CPU’s PECI address. Using the wrong address causes all PECI commands to that client to fail with no response. Check your platform’s hardware schematic for socket-to-address mapping.

Build-Time Configuration (Yocto)

Include PECI sensor daemons in your image and add the kernel config fragment:

# In your machine .conf or image recipe
IMAGE_INSTALL:append = " dbus-sensors"
# meta-myplatform/recipes-kernel/linux/linux-aspeed_%.bbappend
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"
SRC_URI += "file://peci.cfg"

Meson Build Options (dbus-sensors)

When building dbus-sensors from source:

meson setup build -Dpeci=enabled

Entity Manager PECI Configuration

Entity Manager provides the JSON configuration that tells dbus-sensors how to discover and expose PECI sensors. The PECI sensor daemon watches for Entity Manager configuration objects of type XeonCPU and creates hwmon-backed D-Bus sensor objects for each CPU and its DIMMs.

Configuration File

Create a JSON configuration at /usr/share/entity-manager/configurations/:

{
    "Exposes": [
        {
            "Name": "CPU0",
            "Type": "XeonCPU",
            "Bus": 0,
            "Address": "0x30",
            "CpuID": 0,
            "Thresholds": [
                {
                    "Direction": "greater than",
                    "Name": "upper critical",
                    "Severity": 1,
                    "Value": 95
                },
                {
                    "Direction": "greater than",
                    "Name": "upper warning",
                    "Severity": 0,
                    "Value": 85
                }
            ]
        },
        {
            "Name": "CPU1",
            "Type": "XeonCPU",
            "Bus": 0,
            "Address": "0x31",
            "CpuID": 1,
            "Thresholds": [
                {
                    "Direction": "greater than",
                    "Name": "upper critical",
                    "Severity": 1,
                    "Value": 95
                },
                {
                    "Direction": "greater than",
                    "Name": "upper warning",
                    "Severity": 0,
                    "Value": 85
                }
            ]
        }
    ],
    "Name": "PeciSensors",
    "Probe": "TRUE",
    "Type": "Board"
}

Entity Manager Properties for PECI

Property Type Description
Name string Sensor name prefix (e.g., “CPU0”)
Type string Must be XeonCPU for PECI sensors
Bus integer PECI bus number (typically 0)
Address string CPU PECI address in hex (e.g., “0x30”)
CpuID integer CPU socket index (0, 1, 2, 3)
Thresholds array Warning and critical temperature thresholds

Deploying Configuration via bbappend

Install the Entity Manager configuration through your machine layer:

# meta-myplatform/recipes-phosphor/configuration/entity-manager_%.bbappend
FILESEXTRAPATHS:prepend := "${THISDIR}/${PN}:"

SRC_URI += "file://peci-sensors.json"

do_install:append() {
    install -d ${D}${datadir}/entity-manager/configurations
    install -m 0644 ${WORKDIR}/peci-sensors.json \
        ${D}${datadir}/entity-manager/configurations/
}

FILES:${PN} += "${datadir}/entity-manager/configurations/peci-sensors.json"

Porting Guide

Follow these steps to enable PECI thermal monitoring on your platform:

Step 1: Prerequisites

Ensure you have:

  • An ASPEED AST2500 or AST2600 BMC with a PECI pin connected to the host CPU(s)
  • Intel Xeon or compatible CPU(s) supporting PECI
  • A working OpenBMC build environment with your machine layer
  • The host CPU powered on (PECI requires CPU power to respond)

Step 2: Configure the Device Tree

Add the PECI controller and client nodes to your platform device tree:

&peci0 {
    status = "okay";
    peci-client@30 {
        compatible = "intel,peci-client";
        reg = <0x30>;
    };
};

Step 3: Enable Kernel Drivers

Create peci.cfg in your kernel recipe directory and add the bbappend as shown in Build-Time Configuration.

Step 4: Create Entity Manager Configuration

Create the PECI sensor JSON and install it via a bbappend as shown in Entity Manager PECI Configuration.

Step 5: Build and Verify

# Build the image
bitbake obmc-phosphor-image

# Flash and boot the BMC, then verify:

# 1. Check PECI drivers
dmesg | grep -i peci

# 2. Verify PECI devices
ls /sys/bus/peci/devices/

# 3. Test connectivity
peci_cmds Ping -a 0x30

# 4. Check D-Bus sensors
busctl tree xyz.openbmc_project.PECISensor

# 5. Read temperature
busctl get-property xyz.openbmc_project.PECISensor \
    /xyz/openbmc_project/sensors/temperature/CPU0_Temp \
    xyz.openbmc_project.Sensor.Value Value

Verifying PECI Sensors

After booting with the PECI configuration in place and the host CPU powered on, verify each layer of the stack from bottom to top.

Verify Kernel Drivers and Hwmon

# Check PECI controller driver
dmesg | grep -i peci
# Expected: "peci-aspeed 1e78b000.peci-bus: peci bus 0 registered"

# Check for PECI clients
ls /sys/bus/peci/devices/
# Expected: 0-30  0-31

# Check hwmon devices
ls /sys/bus/peci/devices/0-30/peci-cputemp.0/hwmon/
ls /sys/bus/peci/devices/0-30/peci-dimmtemp.0/hwmon/

Read Raw Hwmon Values

# Find and read all PECI hwmon sensors
for d in /sys/class/hwmon/hwmon*; do
    name=$(cat "$d/name" 2>/dev/null)
    if echo "$name" | grep -q peci; then
        echo "=== $d ($name) ==="
        for f in "$d"/temp*_input; do
            label=$(cat "${f%_input}_label" 2>/dev/null || echo "unknown")
            val=$(cat "$f" 2>/dev/null)
            if [ -n "$val" ]; then
                echo "  $label: $((val / 1000))°C"
            fi
        done
    fi
done

Test with peci_cmds

The peci_cmds utility allows you to send raw PECI commands for testing:

# Ping CPU 0
peci_cmds Ping -a 0x30

# Read CPU 0 die temperature
peci_cmds GetTemp -a 0x30

# Read package configuration (TCC activation temp)
peci_cmds RdPkgConfig -a 0x30 -i 0 -p 16

# Read IA MSR (e.g., platform info)
peci_cmds RdIAMSR -a 0x30 -i 0 -m 0xCE

Verify D-Bus Sensors

# List all PECI temperature sensors
busctl tree xyz.openbmc_project.PECISensor

# Read CPU0 die temperature
busctl get-property xyz.openbmc_project.PECISensor \
    /xyz/openbmc_project/sensors/temperature/CPU0_Temp \
    xyz.openbmc_project.Sensor.Value Value

# Read CPU0 DIMM0 temperature
busctl get-property xyz.openbmc_project.PECISensor \
    /xyz/openbmc_project/sensors/temperature/CPU0_DIMM0_Temp \
    xyz.openbmc_project.Sensor.Value Value

# Check threshold status
busctl get-property xyz.openbmc_project.PECISensor \
    /xyz/openbmc_project/sensors/temperature/CPU0_Temp \
    xyz.openbmc_project.Sensor.Threshold.Critical CriticalAlarmHigh

Verify via Redfish

curl -k -u root:0penBmc \
    https://localhost/redfish/v1/Chassis/chassis/Sensors/CPU0_Temp

curl -k -u root:0penBmc \
    https://localhost/redfish/v1/Chassis/chassis/Thermal

Code Examples

Example 1: PECI Health Check Script

A shell script to verify PECI connectivity and read temperatures from all detected CPUs:

#!/bin/bash
# peci_health_check.sh - Verify PECI connectivity and read temperatures

PECI_ADDRS="0x30 0x31"

echo "=== PECI Health Check ==="

# Check kernel drivers
echo ""
echo "--- Kernel Drivers ---"
for mod in peci_aspeed peci_cputemp peci_dimmtemp; do
    if [ -d "/sys/module/$mod" ]; then
        echo "[OK] $mod loaded"
    else
        echo "[FAIL] $mod NOT loaded"
    fi
done

# Check PECI devices
echo ""
echo "--- PECI Devices ---"
ls /sys/bus/peci/devices/ 2>/dev/null || echo "No PECI devices found"

# Ping each CPU and read temperature
echo ""
echo "--- PECI Connectivity ---"
for addr in $PECI_ADDRS; do
    result=$(peci_cmds Ping -a "$addr" 2>&1)
    if echo "$result" | grep -qi "succeed"; then
        temp=$(peci_cmds GetTemp -a "$addr" 2>&1)
        echo "[OK] CPU at $addr: $temp"
    else
        echo "[--] CPU at $addr: not responding"
    fi
done

# Read hwmon PECI sensors
echo ""
echo "--- Hwmon PECI Sensors ---"
for d in /sys/class/hwmon/hwmon*; do
    name=$(cat "$d/name" 2>/dev/null)
    if echo "$name" | grep -q peci; then
        echo "Device: $d ($name)"
        for f in "$d"/temp*_input; do
            [ -f "$f" ] || continue
            label=$(cat "${f%_input}_label" 2>/dev/null || basename "$f")
            val=$(cat "$f" 2>/dev/null)
            if [ -n "$val" ] && [ "$val" != "0" ]; then
                echo "  $label: $((val / 1000))°C"
            fi
        done
    fi
done
echo ""
echo "=== Check Complete ==="

Example 2: Reading PECI Sensors via D-Bus (Python)

#!/usr/bin/env python3
"""Read PECI CPU and DIMM temperatures from D-Bus."""
import subprocess

SERVICE = "xyz.openbmc_project.PECISensor"

def get_sensor_value(path):
    """Read a sensor value from D-Bus using busctl."""
    try:
        result = subprocess.run(
            ["busctl", "get-property", SERVICE, path,
             "xyz.openbmc_project.Sensor.Value", "Value"],
            capture_output=True, text=True, timeout=5,
        )
        if result.returncode == 0:
            parts = result.stdout.strip().split()
            if len(parts) >= 2:
                return float(parts[1])
    except (subprocess.TimeoutExpired, ValueError):
        pass
    return None

def list_peci_sensors():
    """List all temperature sensors from PECISensor service."""
    result = subprocess.run(
        ["busctl", "tree", SERVICE],
        capture_output=True, text=True, timeout=5,
    )
    return [line.strip() for line in result.stdout.splitlines()
            if "/sensors/temperature/" in line]

if __name__ == "__main__":
    sensors = list_peci_sensors()
    if not sensors:
        print("No PECI sensors found. Is the host CPU powered on?")
    else:
        print(f"Found {len(sensors)} PECI sensor(s):")
        for path in sensors:
            value = get_sensor_value(path)
            name = path.split("/")[-1]
            status = f"{value:.1f} C" if value is not None else "unavailable"
            print(f"  {name}: {status}")

See additional examples in the examples/peci/ directory.


Troubleshooting

Issue: PECI Ping Fails (No Response from CPU)

Symptom: peci_cmds Ping -a 0x30 returns an error or times out.

Cause: The CPU is not powered on, the PECI wire is not connected, or the PECI controller driver is not loaded.

Solution:

  1. Verify the host CPU is powered on:
    busctl get-property xyz.openbmc_project.State.Host \
        /xyz/openbmc_project/state/host0 \
        xyz.openbmc_project.State.Host CurrentHostState
    
  2. Check the PECI controller driver loaded:
    dmesg | grep -i peci
    ls /sys/bus/peci/
    
  3. Verify device tree configuration:
    cat /sys/firmware/devicetree/base/ahb/apb/peci-bus@*/status
    

PECI requires the CPU to be powered on and through its reset sequence. If the host is off or in standby, all PECI commands will fail. This is expected behavior, not a bug.

Issue: Kernel Driver Not Loaded

Symptom: dmesg | grep peci shows no output. /sys/bus/peci/ does not exist.

Cause: The PECI kernel modules are not built or not included in the image.

Solution:

  1. Verify kernel config:
    zcat /proc/config.gz | grep -i peci
    
  2. If options are missing, add the kernel config fragment and rebuild.
  3. If built as modules, load manually:
    modprobe peci_aspeed
    modprobe peci_cputemp
    modprobe peci_dimmtemp
    

Issue: Hwmon Devices Not Created

Symptom: PECI ping succeeds, but no hwmon entries appear under /sys/bus/peci/devices/0-30/.

Cause: The peci-cputemp or peci-dimmtemp drivers are not loaded, or the CPU has not completed POST.

Solution:

  1. Check client sub-driver directories:
    ls /sys/bus/peci/devices/0-30/
    
  2. Wait for the CPU to complete POST, then trigger a rescan:
    echo 1 > /sys/bus/peci/rescan
    

Issue: D-Bus Sensors Show NaN

Symptom: busctl get-property returns d nan for PECI sensor values.

Cause: The host is not powered on, or the hwmon file is returning an error.

Solution:

  1. Confirm the host power state is Running.
  2. Read the raw hwmon value directly:
    cat /sys/class/hwmon/hwmon<N>/temp1_input
    
  3. Check the PECISensor daemon logs:
    journalctl -u xyz.openbmc_project.pecisensor -f
    

Issue: DIMM Temperatures Not Available

Symptom: CPU die temperature works, but DIMM temperatures are not exposed.

Cause: The peci-dimmtemp driver did not detect populated DIMM slots, or the CPU model does not support DIMM temperature reading via PECI.

Solution:

  1. Check if peci-dimmtemp created hwmon entries:
    ls /sys/bus/peci/devices/0-30/peci-dimmtemp.0/hwmon/
    
  2. Verify DIMM population using PECI package config:
    peci_cmds RdPkgConfig -a 0x30 -i 0 -p 14
    

Debug Commands

# Check all PECI-related services
systemctl list-units | grep -i peci

# View PECISensor logs
journalctl -u xyz.openbmc_project.pecisensor -f

# Check Entity Manager detected PECI config
journalctl -u xyz.openbmc_project.EntityManager | grep -i peci

# Kernel PECI bus status
ls -la /sys/bus/peci/devices/
dmesg | grep -i peci

# Raw PECI commands
peci_cmds Ping -a 0x30
peci_cmds GetTemp -a 0x30
peci_cmds RdPkgConfig -a 0x30 -i 0 -p 16

References

Official Resources

External Documentation


Tested on: Physical AST2600 EVB with Intel Xeon CPU. PECI is not emulated in QEMU – all PECI commands and sensor readings require real hardware with a powered-on host CPU. Last updated: 2026-02-06